Structural engineering in Puerto Colombia
Structural design and site supervision by the sea, with durability built into the calculation.
Photo: Etienne Girardet / Unsplash
DDES provides structural design, independent design review, technical supervision and construction oversight (interventoría) for projects in Puerto Colombia, Atlántico, under the NSR-10 (Colombia's seismic-resistant building code) and Law 1796 of 2016. Puerto Colombia is in the low seismic hazard zone, with Aa = 0.10 and Av = 0.10. Puerto Colombia is in the Barranquilla metropolitan area, where the DDES office is.
- Seismic hazard
- Low
- Aa / Av
- 0.10 / 0.10
- Ae / Ad
- 0.04 / 0.03
- Department
- Atlántico
What does the NSR-10 require to build in Puerto Colombia?
In reinforced concrete, the NSR-10 accepts structures with minimum energy dissipation capacity (DMI) in the low hazard zone, with the simplest detailing, and for occupancy groups I and II it limits the irregularity checks to a few types (A.3.3.6).
If the geotechnical study gives a type D profile, the Puerto Colombia design spectrum for a residential or office building (occupancy group I) has a plateau of Sa = 0.40 g up to TC = 0.72 s, and TL = 5.76 s. With another soil or another use the values change: work them out with the design spectrum.
What does the sea demand of concrete in Puerto Colombia?
By the sea, what wears a structure down most is not earthquakes but corrosion: concrete exposed to moisture and to chlorides from seawater, salt or sea spray belongs to the NSR-10's exposure class C2, which requires a maximum water-cementitious materials ratio of 0.40, a minimum strength of 35 MPa and no more than 0.15 % water-soluble chlorides in reinforced concrete (tables C.4.2.1 and C.4.3.1). In corrosive environments the code also asks for larger covers or other protection (C.7.7.6).
What should be checked on site?
That the mix meets the specified water-cement ratio, not just the strength; that the spacers guarantee the cover shown on the drawings; and that curing is complete. These are points technical supervision checks before every pour.
When does Law 1796 require review and technical supervision in Puerto Colombia?
The rule is the same throughout the country: when the lot allows more than 2,000 m² to be built, whatever the use, Law 1796 of 2016 requires an independent review of the structural designs before the permit and independent technical supervision during construction. Buildings in occupancy groups III and IV, such as schools and hospitals, require technical supervision whatever the area (A.1.3.9.1). Check your case with the Law 1796 assistant.
DDES services in Puerto Colombia

Structural design
Concrete, steel and masonry buildings designed to the NSR-10, from the first concept to the reinforcement details.

Technical supervision
Independent technical supervision under Law 1796 and Title I of the NSR-10, before every concrete pour.

Assessment and retrofit
Damage assessment, seismic vulnerability and retrofit design for existing buildings.
Technical notes for Puerto Colombia

Concrete near the sea: what the NSR-10 requires against salt air
Exposure class C2, a water-cement ratio of 0.40, 35 MPa and concrete cover: the code's recipe for the coast.

Chlorides and reinforcement: the concrete cover that actually protects
Why the sea breeze corrodes concrete from the inside, and what to specify to prevent it.

When is a crack dangerous?
How to tell a cosmetic crack from one that needs an engineer: width, direction, where it appears and whether it grows.
Common situations
- Adding a second floorBefore adding a floor you need to know whether the house can carry it.
- Home structural retrofitSo an older structure resists what today's code requires.
- Crack assessmentNot every crack is serious, but every crack that grows needs to be studied.
- Warehouse designFrames, roof, floor slab and foundation, designed together.
- Retaining wallsFor basements, level changes and sloping lots.
- Tanks and poolsStructures that must not only stand but also not leak.
- Steel mezzanineMore usable floor area inside the same warehouse or store.
- Building permitWhich structural documents the curaduría asks for and who signs them.
Frequently asked questions
What seismic hazard zone is Puerto Colombia in?
In the low seismic hazard zone, with Aa = 0.10 and Av = 0.10 according to Appendix A-4 of the NSR-10.
Does DDES work in Puerto Colombia?
Yes. DDES works from its office in Barranquilla across Colombia and has done projects in Atlántico. For a proposal, send the architectural drawings and the location of the lot through the contact form or on WhatsApp.
Other cities
- BarranquillaLow hazard
- SoledadLow hazard
- MalamboLow hazard
- GalapaLow hazard
- CartagenaLow hazard
- Santa MartaIntermediate hazard
- MonteríaIntermediate hazard
- SincelejoIntermediate hazard
- ValleduparLow hazard
- RiohachaIntermediate hazard
- YopalHigh hazard
- AguazulHigh hazard
- VillanuevaIntermediate hazard
- TauramenaIntermediate hazard
- MonterreyHigh hazard
- Paz de AriporoIntermediate hazard
- BogotáIntermediate hazard
- MedellínIntermediate hazard
- CaliHigh hazard
- BucaramangaHigh hazard
- CúcutaHigh hazard
- VillavicencioHigh hazard
- IbaguéIntermediate hazard
- PereiraHigh hazard
- ManizalesHigh hazard
- NeivaHigh hazard
- PastoHigh hazard
- ArmeniaHigh hazard
- TunjaIntermediate hazard
- PopayánHigh hazard
Last updated:

Contact
Do you have a project in Puerto Colombia?
Tell us what stage you are at. A DDES engineer replies with a proposal for scope and fees.
Our team works in Spanish. You can write to us in English and we will get back to you.
Photo: Julia Taubitz / Unsplash