Structural engineering in Santa Marta
Structural design, review and technical supervision in an intermediate seismic hazard zone.
Photo: Glenov Brankovic / Unsplash
DDES provides structural design, independent design review, technical supervision and construction oversight (interventoría) for projects in Santa Marta, Magdalena, under the NSR-10 (Colombia's seismic-resistant building code) and Law 1796 of 2016. Santa Marta is in the intermediate seismic hazard zone, with Aa = 0.15 and Av = 0.10. DDES serves projects in Santa Marta from its office in Barranquilla, with nationwide coverage within Colombia.
- Seismic hazard
- Intermediate
- Aa / Av
- 0.15 / 0.10
- Ae / Ad
- 0.10 / 0.04
- Department
- Magdalena
What does the NSR-10 require to build in Santa Marta?
In reinforced concrete, the intermediate hazard zone no longer allows minimum dissipation (DMI): the structure is designed with moderate (DMO) or special (DES) energy dissipation capacity, with more reinforcement detailing requirements.
If the geotechnical study gives a type D profile, the Santa Marta design spectrum for a residential or office building (occupancy group I) has a plateau of Sa = 0.56 g up to TC = 0.51 s, and TL = 5.76 s. With another soil or another use the values change: work them out with the design spectrum.
Why is Santa Marta designed differently from Barranquilla?
Because it is in the intermediate seismic hazard zone: Aa = 0.15, against 0.10 in Barranquilla. It is the only capital in the Caribbean region where the acceleration coefficient Aa exceeds the velocity coefficient Av, and that raises the plateau of the spectrum, the short-period range where low, stiff buildings fall. By the sea, durability adds to it: concrete exposed to moisture and to chlorides from seawater, salt or sea spray belongs to the NSR-10's exposure class C2, which requires a maximum water-cementitious materials ratio of 0.40, a minimum strength of 35 MPa and no more than 0.15 % water-soluble chlorides in reinforced concrete (tables C.4.2.1 and C.4.3.1).
And hillside lots?
The NSR-10 site coefficients Fa and Fv do not include hillside effects. Where there are any, they must be considered with the municipality's regulations or with site-specific studies by the geotechnical engineer (A.2.4.5.7). In a city surrounded by hills, it is worth asking for it from the geotechnical study onward.
When does Law 1796 require review and technical supervision in Santa Marta?
The rule is the same throughout the country: when the lot allows more than 2,000 m² to be built, whatever the use, Law 1796 of 2016 requires an independent review of the structural designs before the permit and independent technical supervision during construction. Buildings in occupancy groups III and IV, such as schools and hospitals, require technical supervision whatever the area (A.1.3.9.1). Check your case with the Law 1796 assistant.
DDES services in Santa Marta

Structural design
Concrete, steel and masonry buildings designed to the NSR-10, from the first concept to the reinforcement details.

Independent design review
Review of structural designs by others, required on projects of more than 2,000 m².

Technical supervision
Independent technical supervision under Law 1796 and Title I of the NSR-10, before every concrete pour.
Technical notes for Santa Marta

Seismic hazard on the Caribbean coast: city by city under the NSR-10
Barranquilla and Cartagena are in the low hazard zone; Santa Marta, Montería, Sincelejo and Riohacha, in the intermediate zone.

Occupancy groups: why a school or a clinic is designed stronger
The NSR-10 sorts buildings into four groups and raises the design forces by up to 50%.

Concrete near the sea: what the NSR-10 requires against salt air
Exposure class C2, a water-cement ratio of 0.40, 35 MPa and concrete cover: the code's recipe for the coast.
Common situations
- Adding a second floorBefore adding a floor you need to know whether the house can carry it.
- Home structural retrofitSo an older structure resists what today's code requires.
- Crack assessmentNot every crack is serious, but every crack that grows needs to be studied.
- Warehouse designFrames, roof, floor slab and foundation, designed together.
- Retaining wallsFor basements, level changes and sloping lots.
- Tanks and poolsStructures that must not only stand but also not leak.
- Steel mezzanineMore usable floor area inside the same warehouse or store.
- Building permitWhich structural documents the curaduría asks for and who signs them.
Frequently asked questions
What seismic hazard zone is Santa Marta in?
In the intermediate seismic hazard zone, with Aa = 0.15 and Av = 0.10 according to Appendix A-4 of the NSR-10.
Does DDES work in Santa Marta?
Yes. DDES works from its office in Barranquilla across Colombia. For a proposal, send the architectural drawings and the location of the lot through the contact form or on WhatsApp.
Other cities
- BarranquillaLow hazard
- SoledadLow hazard
- Puerto ColombiaLow hazard
- MalamboLow hazard
- GalapaLow hazard
- CartagenaLow hazard
- MonteríaIntermediate hazard
- SincelejoIntermediate hazard
- ValleduparLow hazard
- RiohachaIntermediate hazard
- YopalHigh hazard
- AguazulHigh hazard
- VillanuevaIntermediate hazard
- TauramenaIntermediate hazard
- MonterreyHigh hazard
- Paz de AriporoIntermediate hazard
- BogotáIntermediate hazard
- MedellínIntermediate hazard
- CaliHigh hazard
- BucaramangaHigh hazard
- CúcutaHigh hazard
- VillavicencioHigh hazard
- IbaguéIntermediate hazard
- PereiraHigh hazard
- ManizalesHigh hazard
- NeivaHigh hazard
- PastoHigh hazard
- ArmeniaHigh hazard
- TunjaIntermediate hazard
- PopayánHigh hazard
Last updated:

Contact
Do you have a project in Santa Marta?
Tell us what stage you are at. A DDES engineer replies with a proposal for scope and fees.
Our team works in Spanish. You can write to us in English and we will get back to you.
Photo: Julia Taubitz / Unsplash