Barranquilla · — Request a proposal
Seismic hazard

Seismic hazard in Caquetá

Aa, Av, Ae and Ad for its 16 municipalities under the NSR-10.

Photo: Sven Mieke / Unsplash

According to Appendix A-4 of the NSR-10, of the 16 municipalities of Caquetá, 1 in the high hazard zone, 13 in the intermediate hazard zone and 2 in the low hazard zone. The capital, Florencia, has Aa = 0.20 and Av = 0.15, intermediate hazard. Across the department, Aa ranges from 0.05 to 0.25 and Av from 0.05 to 0.20.

Municipalities
16
Capital
Florencia
Aa / Av of the capital
0.20 / 0.15
High hazard
1
Intermediate hazard
13
Low hazard
2

Municipalities of Caquetá

Values from Appendix A-4 of the NSR-10. Tap a municipality to open its design spectrum.

Source: NSR-10, Title A, Appendix A-4. Zone according to A.2.3.
MunicipalityCodeAaAvZoneAeAd
Florencia180010.200.15Intermediate0.100.05
Albania180290.150.15Intermediate0.060.04
Belén de los Andaquíes180940.200.15Intermediate0.090.05
Cartagena del Chairá181500.050.15Intermediate0.040.02
Currillo182050.150.20Intermediate0.060.03
El Doncello182470.150.15Intermediate0.060.03
El Paujil182560.150.15Intermediate0.060.03
La Montañita184100.100.15Intermediate0.050.03
Milán184600.050.15Intermediate0.040.02
Morelia184790.150.15Intermediate0.060.03
Puerto Rico185920.150.15Intermediate0.070.03
San José de la Fragua186100.250.20High0.090.05
San Vicente del Caguán187530.050.05Low0.040.02
Solano187560.050.05Low0.040.02
Solita187850.050.15Intermediate0.040.02
Valparaíso188600.050.15Intermediate0.040.03

What does it mean for design in Caquetá?

Municipalities in the high hazard zone. In reinforced concrete, the NSR-10 only accepts systems with special energy dissipation capacity (DES) in the high hazard zone, the most demanding detailing in the code: confinement of columns and joints, and strict drift control.

Municipalities in the intermediate hazard zone. In reinforced concrete, the intermediate hazard zone no longer allows minimum dissipation (DMI): the structure is designed with moderate (DMO) or special (DES) energy dissipation capacity, with more reinforcement detailing requirements.

Municipalities in the low hazard zone. In reinforced concrete, the NSR-10 accepts structures with minimum energy dissipation capacity (DMI) in the low hazard zone, with the simplest detailing, and for occupancy groups I and II it limits the irregularity checks to a few types (A.3.3.6).

The municipality's value is only the starting point: the soil profile sets the coefficients Fa and Fv, and the occupancy group sets the importance factor. Work out the full spectrum with the NSR-10 design spectrum, or look up another municipality in the seismic hazard tool.

Frequently asked questions

What seismic hazard zone is Florencia in?

In the intermediate seismic hazard zone: Aa = 0.20 and Av = 0.15, according to Appendix A-4 of the NSR-10.

Which municipalities of Caquetá have the highest seismic hazard?

The department's highest coefficient, 0.25, is found in San José de la Fragua.

How many municipalities of Caquetá are in each seismic hazard zone?

Of 16 municipalities, 1 are in the high hazard zone, 13 in the intermediate zone and 2 in the low zone (NSR-10, Appendix A-4).